All projects
Raleigh Transit — Equipment Mezzanine
Needs ConfirmationRaleigh Transit Authority · Construction · Last source update May 12, 2026
46
Moderate
risk score
Current truth
The mezzanine footprint changed after field measurement. The change was agreed verbally on the May 7 call but no change order has been issued and the shop drawings still show the old dimension.
AI confidence79%
Source coverage68%
Open questions
- Which footprint governs — the original drawing or the field measurement?
Next recommended action
Issue a change order for the revised footprint and reissue shop drawings before grating is cut.
Resolve in Chat
6
Confirmed requirements
3
Open requirements
1
Conflicts
0
Untracked commitments
Summary
Bolted structural steel equipment mezzanine with grating and ship's ladder. A field-measured dimension change was agreed in a meeting but not issued as a change order.